AIT is pleased to announce that the following laboratories have the necessary facilities, equipment, and at least one analyst certified to implement EPA Method-6800 compliant elemental and speciated Chromium analysis. The process by which AIT qualifies and certifies each laboratory, under its “proficiency certification program”, involves an interactive approach which includes evaluation of the laboratory’s capabilities, availability of at least one analyst trained and capable of running an ICP-MS and a front-end LC separation capability. Then, through on-site and off-site training, and using a set of NIST-traceable natural standards, isotopically spiked standards and a combination of matrices with different levels trivalent and hexavalent Chromium concentrations specifically designed for the certification process, the analyst is asked to perform analyses in triplicates and report the data to a reference laboratory (RL) that is Method-6800-certified by AIT and New Jersey’s Department of Environmental Protection. The analyst is certified when the RL confirms that reported data are within an acceptable window of accuracy. For additional information about the CAPTK™ product line, please contact the company.

 

TM - CAPTK is a trademark of Applied Isotope Technologies and refers to the Chromium Analysis Proficiency Testing Kit associated with the AIT’s certification program associated with Chromium analysis.

 

List of Laboratories that are certified by AIT for having suitable facilities, equipment and an analyst capable of EPA Method 6800 compliant Chromium analysis.

 

Applied Speciation and Consulting, LLC

Contact person: Hakan Gurleyuk

Email: hakan@appliedspeciation.com

953 Industry Drive

Tukwila, WA 98188

Ph: 206-219-3779

Fx: 206-388-3485

www.appliedspeciation.com

 

 

Severn-Trent Laboratories

Email: RVicinie@stl-inc.com

Contact person: Rusty Vicinie

301 Alpha Drive

Pittsburgh, PA 15238

Ph: 412-963-7058

Fx: 412-963-2468

www.stl-inc.com/labs/labs.htm

 

Duquesne University – Reference Laboratory

Contact persons:

Prof. H. M. ‘Skip’ Kingston

Dr. Mizan Rahman

Department of Chemistry and Biochemistry and Center for Environmental Research and Education

600 Forbes Avenue

308 Mellon Hall

Pittsburgh, PA 15282

Ph: 412-999-8975 (Prof. Kingston)

Ph: 412-477-9474 (Dr. Rahman)

Email:   Kingston@duq.edu

            Rahman533@duq.edu


 

AIT provides advice, information, technical support and IDMS/SIDMS proficiency testing products that enable environmental analytical laboratories to implement speciated analyses using IDMS and SIDMS methods. Typically, related AIT products and services include the following:

- Evaluation of analytical capabilities of the applicant laboratory from SIDMS perspective. The EPA Method 6800 (SIDMS) utilizes an Inductively Coupled Plasma Mass Spectrometer (ICP-MS) and requires, at the front-end, IC or HPLC separation system with non-metallic components. After the evaluation, AIT provides its conclusions and recommendations. For laboratories that are yet to automate injection, AIT recommends and provides information about an auto-injector and separation system made by Metrohm-Peak (www.mp-ic.com). This system is compatible and can be integrated with most ICP-MS instruments.

- Method 6800 proficiency testing and certification for IDMS (total chromium and mercury analysis), using pre-spiked standards.

- Method 6800 proficiency testing and certification for IDMS and SIDMS (speciated metal analysis) using soil extract standards.

- Method 6800/3060A/3052 proficiency testing and certification for IDMS and SIDMS using solid matrice.

Note: The EPA Method 6800 (SIDMS) utilizes an Inductively Coupled Plasma Mass Spectrometer (ICP-MS) and requires, at the front-end, an IC or HPLC separation system with non-metallic components. After the evaluation, AIT provides its conclusions and recommendations. For laboratories that are yet to automate injection, AIT recommends and provides information about an auto-injector and separation system made by Metrohm-Peak (www.mp-ic.com). This system is compatible and can be integrated with most ICP-MS instruments.

NOTICES:
- It is important note that AIT's Method 6800 proficiencey testing service does not replace certification protocols that are required by environmental agencies in individual states in the US.

- SIDMS is a patented technology. AIT is the only company authorized to make and sell SIDMS-based products.


 

spacer